PMD Study & Measurement – Fixed Analyzer Method

Published online: Dec 22, 2015 Full Text: PDF (1.32 MiB) DOI: 10.24138/jcomss.v11i4.98
Cite this paper
Authors:
Rastislav Motuz, Petr Munster, Miloslav Filka

Abstract

The paper theoretically describes Polarization Mode Dispersion (PMD) which is important parameter in high-speed optical networks. Furthermore, compensation methods and measurement principles are presented. Main attention is given to Fixed Analyzer (FA) method that uses common research laboratory equipment in setup. We performed practical measurement of the PMD by using Optical Spectrum Analyzer (OSA) Anritsu MS9740A, in-line polarizers and a polarization controller. To verify the accuracy of measurements Reference Measurement (RM) using a modular platform EXFO FTB-200 in combination with CD/PMD module EXFO FTB-5700 was performed. Moreover, PMD etalons with defined values of delay was used for measurement. All results were evaluated in comparison with defined limit values.

Keywords

PMD measurement, Fixed Analyzer method, fiber, polarization, dispersion, DGD
Creative Commons License 4.0
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.